CH2 Expanding Capabilities

With the introduction of our CH2 tester three years ago we expanded the capabilities of our popular CH+ high-voltage harness tester by adding key features such as the ability to test up to 20,000 points, real vs. total current, voltage ramp, and more.

We keep adding features to the CH2. Check out these important new capabilities!

 
  • DWV to 1500VAC
  • Energize Relays and other devices
  • Use Custom Instructions to integrate external meters/power supplies
  • Adapt to your current mating cables with Adapter Panel System
 



CH2 - 1500VAC Power Supply

quickview1 (8K)

ch2-1500v (18K)

The new xHV power supply for the CH2 allows you to set a DWV current leakage threshold of up to 5mA (real) and 22mA (total) current. When used with HV scanners you can now test up to 1500VAC. The extended leakage current settings allow you to test more capacitive assemblies than before. Cable capacitance increases with length, so this means you can now test much longer cables than was possible before with the CH2 tester.

ch2-1500-back-275 (9K)

More Info. - Hipot Testing with AC Voltages

The CH2 Information Page




CH2 - Energization Box

quickview1 (8K)

ch2-energize-400 (27K)

External Power (Energization) Module for powering relays and other devices. The Cirris' "e-module" or External Power Energization module allows you to provide external power to points in your device under test. You can energize relays, power lamps, and make other tests that require external power to be provided.
  • Energization Points: 160 - 800 Points (in 160 pt. increments)
  • Max Current: 1 AMP
  • Fixed Voltage Supplies: 5, 12, 15, 24 & 48 Volts.
  • Agilent Variable Supply: 0 to 60 Volts.
  • Interfacing to E-Unit: Standard AC61-KF cabling

powerplugture-300 (8K)

Link to Energization Box Page and Video!




CH2 - Custom Instructions

quickview1 (8K)

Agilent-34410A-300 (11K)

keithley-2400 (10K)

The Custom Instructions is an add-in set of test instructions that can be used with the CH2 in order to expand the capability of the tester. With custom instructions you can integrate external meters, such as a Keithley 2400 or Agilent 34410A series, to make high accuracy measurements using those instruments. You can integrate a variable power supply when using the Energization Module, allowing you to select different voltages for different applications in the same test program. Custom Instructions open up a whole new world of applications using the CH2 tester.
  • Test: Transzorbs, Zener Diodes, Gas Discharge Tubes etc.
  • Test Relays: Single Coil, Multi Coil, Pull-in-voltages, Drop-out-voltages etc.
  • Test Light/Indicators: Single Lamp to 60V, Multi Lamps up to 60V
  • Test Leakage Current: Diodes, Transistors, MOSFET's, Integrated Circuits, etc.
  • Highly Accurate Voltage or Current Measurements: With integrated Keithley 2400 series meter.
 



CH2 - Adapter Panel System

quickview1 (8K)

cassette-400 (45K)

The adapter panel mounts directly to the front of the CH2 tester and allows you to quickly and easily adapt from the 32 pin Eurodin style connectors on the front of the tester to mating connectors of your choice.