Cable Analyzer Home   Cable Testers and Harness Testers Made Easy!

 

                Cable Testing Products        Support        Information Center        About Us        Contact Us

 

easy-wire CH2 Specifications.

Capacity Expandable from 160 to 20,000 points in 160 -point increments
Continuity Test - 2 wire: Voltage:   standard 2.5 volts
Current:   1uA to 10mA
Resistance:   0.1 ohm to 1M ohm ±2% ±0.1 ohm
Continuity Test - 4 wire: Voltage:   standard 2.5 volts
Current:   (.001 ohm - 1 ohm)-2A (1 ohm - 10 ohm)-200mA (10 ohm - 100 ohm) -20mA
Resistance:   .001 ohm to 100 ohm ±2% ±0.001 ohm
Capacitance:   1pF to 1000µF ±10% ±50pF;
Insulation Test: Voltage:    100 to 1500VDC or 100 to 1000VAC (50 Volt steps) ±5% ±5V
Resistance:   5M ohm to 1000M ohm ±10%
Dielectric Withstand Test: Voltage:   100 to 1500VDC or 100 to 1000VAC (50 Volt steps) ±5% ±5V
Current Limit:  (DC) 0.1mA to 2.5mA   (AC) 0.1mA to 1.5mA (RMS)
Dwell:   (DC) 10ms to 120 sec.    (AC) 17ms to 120 sec. (1 to 7200 cycles)
Test Rate:   256 points per second or faster (typical)
Max Capacitance Per Net: 15nF @ 1500VDC, 2.5nF @ 1000VAC
HV Energy Limit: 35 mJoules
Digital Input/Output 8 Inputs / 8 Outputs, 30V Open collector, T1 compatible. +12V and +5V each current limited to 500mA
Hot Plugging Scanner nodes and base units will survive hot plugging between boxes and between stacks of boxes.
External Relay Actuation 160 to 800 points - in 160 point increments (requires optional relay energization hardware).
Test Point Connector 96 pos. FEMALE VME Eurocard connector-32 pos. loaded
Computer Requirements CPU Speed: 1.6 GHz or faster, OS: Windows 2000 or XP(recommended), Disk Space: 5GB(min) 10G(recommended), RAM: 512M (min) 1G (recommended), Video Memory: 64 Meg RAM, USB Ports: 1 USB (min) 2 USB (recommended) (2.0 Compatible), CD-ROM Drive and Sound card are required. Serial Port: 1 port, Display resolution: 1024 X 768 or better.
Server Requirements:    Operating System: Windows 2000 or 2003 Server. RAM: 1Gig. Disk Space: 10G (min).
Disbributed Test Maximum distance from Base unit: 200 ft.
Power 105-135VAC, 60 Hz. 60 Watts (210-260VAC 50 Hz. optional)
Probe Connector 1 per scanner node - 2 RS-422, 1 test point, ±12V @ 100mA power.
Size (each box) 6.125" tall x 17" wide x 17" deep (16 x 42 x 42 cm)
Weight (each box) 20 lbs. (9 kg)
Temperature Specified: Operational 10 to 40 degrees C; Storage -40 to 70 degrees C
Humidity 0 to 95% RH   (WARNING, I.R. and DWV test results will degrade when Relative Humidity exceeds 75%)
Warranty One year parts and labor.   Replacement modules available next working day.



Cirris Systems- Our Products - Testers - easy-wire CH2 - Specifications.
Toll-free 1-800-441-9910